home *** CD-ROM | disk | FTP | other *** search
/ EnigmA Amiga Run 1997 July / EnigmA AMIGA RUN 20 (1997)(G.R. Edizioni)(IT)[!][issue 1997-07 & 08][EAR-CD IV].iso / lightwave / lwmlist / 95.lightwave-08 / 000413_owner-lightwav…mail.webcom.com_Mon Aug 21 21:58:20 1995.msg < prev    next >
Internet Message Format  |  1995-09-02  |  2KB

  1. Received: by mail.webcom.com
  2.     (1.37.109.15/16.2) id AA267177499; Mon, 21 Aug 1995 21:58:20 -0700
  3. Return-Path: <owner-lightwave@mail.webcom.com>
  4. Received: from netcom15.netcom.com by mail.webcom.com with ESMTP
  5.     (1.37.109.15/16.2) id AA266077453; Mon, 21 Aug 1995 21:57:34 -0700
  6. Received: by netcom15.netcom.com (8.6.12/Netcom)
  7.     id VAA25833; Mon, 21 Aug 1995 21:37:46 -0700
  8. Date: Mon, 21 Aug 1995 21:37:46 -0700 (PDT)
  9. From: John Gross <jgross@netcom.com>
  10. Subject: Re: 2 Machine Rendering
  11. To: Sean Moyer <graphics@usa1.com>
  12. Cc: lightwave@mail.webcom.com
  13. In-Reply-To: <v01510100ac5eaeb078a6@[204.249.225.109]>
  14. Message-Id: <Pine.3.89.9508212142.A23436-0100000@netcom15>
  15. Mime-Version: 1.0
  16. Content-Type: TEXT/PLAIN; charset=US-ASCII
  17. Sender: owner-lightwave@mail.webcom.com
  18. Precedence: bulk
  19.  
  20.  
  21. On Mon, 21 Aug 1995, Sean Moyer wrote:
  22. > >By the way, for better results, do not render frames 1-100 on the first
  23. > >computer and frames 101-200 on the second. What works better is to tell
  24. > >computer #1 to do frames 1-199, frame step = 2, so it does all the odd
  25. > >frames, and tell computer #2 to do frames 2-200, frame step = 2, so it does
  26. > >all the even frames. That way, the two computers stay fairly neck-and-neck
  27. > >as far as the rendering go.
  28. > Actually - the best way to render on 2 machines (IMHO) is as follows:
  29. > (Assume a 200 frame Render)
  30. > Machine 1:  Frame 1 to 200 step 1
  31. > Machine 2:  Frame 200 to 1 step -1
  32. I disagree. I've found that it's better to split up the rendering as you 
  33. described above amongst the available machines. If you have 1000 frames 
  34. to render on 6 machines, set it up so you do:
  35.  
  36. 1-1000, Frame Step 6
  37. 2-1000, Frame Step 6
  38. 3-1000, Frame Step 6
  39. etc.
  40.  
  41. This way if you have to stop machines, it is easier to start re-rendering 
  42. as all the frames to render will be at the end and you won't have to 
  43. search and patch.
  44.  
  45. JG
  46. --
  47. John Gross <jgross@netcom.com> sent this message.
  48. To Post a Message           : lightwave@webcom.com
  49. Un/Subscription Requests To : lightwave-request@webcom.com
  50. (DIGEST)                 or : lightwave-digest-request@webcom.com
  51. Administrative Items To     : owner-lightwave@webcom.com